TV100 Standard &TV100K Cooled Twin-Plate Mini-Gel Electrophoresis Units

TV100_TV100k_IMG

TV100 Standard &TV100K Cooled Twin-Plate Mini-Gel Electrophoresis Units

  • Catlog No.:
  • Make:
  • Download Brochure:
  • Usage:
The TV100 and TV100K twin-plate 10 x 10cm (W x H) mini-gel units are ideal cost-effective solutions for standard PAGE applications, using self-cast or commercially available precast gels.
BENEFITS INCLUDE
Twin-plate 10 x 10cm mini-gel unit
a simple cost-effective solution for PAGE techniques using either self-cast or precast gels
Two versions available:
Standard TV100 – non-cooled Cooled TV100K – a cooling coil in the bottom of the gel tank for faster higher voltage electrophoretic separations
Enhanced cooling
in the TV100K – snap-lock connectors allow the TV100K to be connected to the JULABO chiller unit
Compatible
with commercially available 10 x 10cm precast gels
SERVA precast gels
available especially for the TV100-GRM (see page 141)
Optional TV100-SGB silicone gasket
allows the GRM to be adapted for the ‘non-eared’ or short glass plates of major alternative brands
Gel casting
either with tape or the optional TV100-CB casting base or TV100-MC2 and TV100-MC10 2 and 10 gel multicasters
Float glass plates
2mm thick – guarantee uniform gel thickness and even sample migration, and with ground edges to inhibit sample leakage during casting
Single screws
at either side each gelclamping plate – act in conjunction with a counterbalanced, dovetailed silicone gasket to disperse pressure evenly along the height and breadth of the gel as the screws are tightened
Low buffer volumes
within the inner chamber of the GRM and gel tank economises buffer consumption
Colour-coded combs and spacers
available in 0.75, 1, 1.5 and 2mm thicknesses
Smaller footprint area
occupies minimal bench space
TECHNICAL SPECIFICATION
TV100 TV100K
Unit Dimensions (W x D x H) 20 x 15 x 14cm 28 x 15 x 18cm
Inner Tank Dimensions (W x D x H) 16.5 x 11 x 11.5cm 16.5 x 11 x 15cm
Plate Dimensions (W x H x T) 10 x 10 x 0.2cm 10 x 10 x 0.2cm
Standard Spacer Dimensions (W x H x T) 1 x 10 x 0.1cm 1 x 10 x 0.1cm
Active Gel Dimensions (W x H) 8 x 8.5cm 8 x 8.5cm
Maximum Sample Capacity 2 x 20 2 x 20
Recommended Buffer Volume
Inner Buffer 90ml
Chamber
Inner Buffer 90ml
Chamber
Gel Tank 1200ml Gel Tank 1600ml
Recommended Running Conditions for Denaturing/Native PAGE Gel
Voltage 50 – 100V
(5 – 10V/cm)
Voltage 100 – 150V
(10 – 15V/cm)
Current 5 – 10mA Current 10 – 15mA
Time 1.5 – 2.5h Time 1 – 1.75h
Snap-lock Connectors for Cooling Coil
Inner Diameter n/a Inner Diameter 10mm
Outer Diameter n/a Outer Diameter 12mm
Quick-fit Tubing
Inner Diameter n/a Inner Diameter 10mm
Outer Diameter n/a Outer Diameter 12mm
Power Output Connectors (diameter) Shrouded, 4mm Shrouded, 4mm
Recommended Power Supplies Consort EV243 Consort EV243

Other models

TV100Y Standard &TV100YK Cooled Twin-Plate Mini-Gel Electrophoresis Units